Ground-mount PV · Türkiye · 2017

2.44 MWp Solar Plant in Selim on ISOGROUND Ground Mounts

Module rows on the snowy site
In brief

ISOTEC supplied the ISOGROUND mounting system for a 2.44 MWp ground-mount solar project of four sites in Selim, Kars; the structural reports and material lists date from 2017. The tables are in a 4H layout at a 30° tilt, with posts driven 1.8 m into the ground.

The project

Four sites on a snowy plain

The plant stands in the Selim district of Kars at 1,885 m above sea level, on flat, treeless ground reaching to the horizon. The photo was taken in winter: modules run in rows through the snow inside a fenced site, with construction machinery and small site buildings in the background.

The project consists of four separate sites, all using the ISOGROUND ground-mount system. The standard table is 4x10: four landscape rows of ten modules (1648 × 995 mm) at a 30° tilt. The four sites have 235 tables in total, 217 of type 4x10 and 18 of type 4x5.

The posts were driven 1.8 m into the ground. Posts, vertical beams and horizontal purlins are St52 steel. A separate structural report was prepared for each site, based on snow zone 4, seismic zone 2 and an altitude of 1,885 m.

Section · schematic
25°2 modules portrait (2V) · 2 × 2382 mmrafter + purlinsfront postrear postdriven pile, no concreteSOUTHNORTH
General ISOGROUND TWO section; it does not show this project's dimensions and is schematic.
Technical details
Module size
1648 × 995 mm
Table types
4x10 · 4x5 landscape
Tables
235 · four sites
Tilt
30°
Foundation
Driven piles · 1.8 m
Material
St52 steel
Snow zone
Zone 4
Seismic zone
Zone 2
Structural report
One per site
FAQ

Which mounting system was used in this project in Selim?

ISOTEC's ground-mount system ISOGROUND. The tables are of types 4x10 and 4x5, with four landscape module rows at a 30° tilt.

How many sites does the project have?

Four separate sites with 235 tables in total.

How were the posts fixed in the ground?

The posts were driven 1.8 m into the ground.

Which climate and seismic conditions were used in the structural design?

The structural report for each site is based on snow zone 4, seismic zone 2 and an altitude of 1,885 m.

From the same country

More ISOGROUND projects

Planning a ground-mount project?

Send us the slope, the soil report and the module size, and we will prepare an ISOGROUND quotation with a project-specific structural analysis.

Erkan Öztürk

Erkan Öztürk

Founder & CEO @ ISOTEC
Solar Mounting Systems