Ground-mount PV · Germany · 2023

11.85 MWp Solar Plant in Dohndorf on ISOGROUND TWO Ground Mounts

During installation: rows with and without modules
In brief

In 2023 ISOTEC designed, manufactured and delivered the ISOGROUND TWO mounting system for an 11.85 MWp ground-mount solar plant in Dohndorf, Germany. The plant uses 21,550 modules of 550 Wp on 447 tables, mostly in a 2V25 layout, a 20° tilt and driven steel posts.

The project

447 tables on farmland

The plant stands on flat ground surrounded by fields in Dohndorf; its 21,550 modules are spread over 447 tables.

For this site ISOTEC designed the ISOGROUND TWO ground-mount system in a 2V25 layout: each table carries 50 modules of 550 Wp, in two portrait rows of 25. Of the 447 tables, 421 are 2V25; the rest are 2V10 and 2V5 frames. The tilt is 20° and the lower module edge sits 800 mm above ground. Edge and inner frames differ in frame count and driving depth: the front posts were driven 1.0 m, the rear posts 2.1 m on the edge frames and 1.4 m on the 182 inner frames.

The posts are C 110x60x15x3 profiles (S355; on the 182 inner frames the front post is C 100x40x15x3), the beams C 90x45x12x2 (S350GD) and the purlins Z 90x55x10x1.5, joined with M12 A2-70 bolts. Two separate structural reports to DIN EN 1991, one for the inner and one for the edge frames, are based on snow load zone 2 (sk 0.85 kN/m²) and wind zone 2.

Section · drawn to scale
20°800mm2,600 mm2 modules portrait (2V) · 2 × 2278 mmrafter + purlinsfront postrear postdriven pile, no concreteSOUTHNORTH
Dimensions from this project's production sheet. Lower module edge 800 mm above ground, 2,600 mm between posts, 20° tilt. Bracing and the differing driving depths omitted for clarity.
Technical details
Modules
21,550 × 550 Wp
Module size
2278 × 1134 mm
Tables
447 tables · 2V25 / 2V10
Tilt
20°
Ground clearance
800 mm
Driving depth
front 1.0 · rear 1.4–2.1 m
Material
S355 · S350GD
Frame spacing
N–S 2,600 · E–W 2,100–2,700
Snow load zone
2 · sk 0.85 kN/m²
Wind zone
2
Structural report
DIN EN 1991 · 2 reports
Scope
Design, production, delivery
FAQ

Which mounting system was used at this plant in Dohndorf?

ISOTEC's double-post ground-mount system ISOGROUND TWO. Most tables use a 2V25 layout with 50 portrait modules each; there are 447 tables in total.

How were the posts fixed in the ground?

The posts were driven into the ground: the front posts 1.0 m, the rear posts between 1.4 m and 2.1 m.

Which loads was the structure designed for?

Two separate structural reports, one for the inner and one for the edge frames, are based on DIN EN 1991 with snow load zone 2 (sk 0.85 kN/m²) and wind zone 2.

What is the capacity of the plant?

With 21,550 modules of 550 Wp the installed capacity is 11.85 MWp (11,852.5 kWp).