Ground-mount PV · Türkiye

Ground-Mount Solar Plant in Yeşilova, Burdur, on ISOGROUND TWO

Frame rows before module mounting, sunset
In brief

ISOTEC supplied the ISOGROUND TWO mounting system for a ground-mount solar plant in Yeşilova, Burdur. The steel frames use a 2×8 layout with 16 modules of 320 Wp each, at a 30° tilt, and the posts are fixed on driven piles.

The project

Steel frame rows at Yeşilova before the modules

The plant stands in the Yeşilova district of Burdur, on open ground at an altitude of 1,304 m. The photo was taken at the start of installation, before any modules were fitted: long rows of steel frames with front and rear posts and diagonal bracing catch the evening sun.

The plant uses the ISOGROUND TWO ground-mount system. Each frame carries 16 modules of 320 Wp in a 2×8 layout at a 30° tilt; the steel frames with front and rear posts support the module rows as one structure.

The posts were fixed by pile driving, and a pile driving and pull-out test was carried out on site. The structural calculation is based on snow zone II, seismic zone I and soil class Z2.

Section · schematic
25°2 modules portrait (2V) · 2 × 2382 mmrafter + purlinsfront postrear postdriven pile, no concreteSOUTHNORTH
The drawing shows the general structure of a double-post ISOGROUND frame; it does not show this project's dimensions.
Technical details
Module power
320 Wp
Module size
1648 × 995 mm
Frame
2×8 · 16 modules
Tilt
30°
Foundation
Driven piles
Site test
Driving and pull-out test
Soil
Class Z2
Snow zone
Zone II · 1,304 m
Seismic
Zone I
FAQ

Which mounting system was used at this plant in Yeşilova?

ISOTEC's double-post ground-mount system ISOGROUND TWO. The frames use a 2×8 layout and carry 16 modules each.

What tilt do the modules have?

The modules sit at a 30° tilt; each frame carries 16 modules of 320 Wp.

How were the posts fixed in the ground?

The posts were fixed by pile driving, and a pile driving and pull-out test was carried out on site.

Which conditions was the structure designed for?

The structural calculation is based on 1,304 m elevation, snow zone II, seismic zone I and soil class Z2.