Pitched-roof PV · Türkiye · 2020

894.72 kWp Sandwich-Panel Roof PV in Gaziantep on ISOTRAP S85 Mounts

The shed roofs that carry the plant
In brief

In 2020 ISOTEC supplied the ISOTRAP S85 mounting system for an 894.72 kWp rooftop solar plant in Şehitkamil, Gaziantep. The plant has 2,796 modules of 320 Wp on short aluminium S85/540 profiles that sit across the ribs of sandwich-panel roofs, fixed with sealed screws and EPDM rubber gaskets.

The project

Sandwich-panel roofs on long sheds

The plant sits on the long shed roofs of a facility on open ground in Şehitkamil, Gaziantep. The roofs are sandwich panels in grey with orange stripes; the structural report assumes a 7° roof pitch, a 500 mm rib spacing and a 0.50 mm sheet thickness. The photos show the stage before the modules arrived, with the profiles being laid out on the roof.

The ISOTRAP S85 system uses short aluminium profiles for roofs like these: S85 profiles, 540 mm long and 85 mm high, sit across the ribs and bridge two neighbouring rib crests. The modules rest on the profiles with EasyClamp mid and end clamps.

The profiles are fixed to the rib crests with sealed, self-drilling 5.5 × 25 bimetal screws; a 22 × 87 × 3 mm EPDM rubber gasket underneath keeps the sheet watertight where it is pierced. The structural report was prepared for snow zone 3, with a ground snow load of 1.25 kN/m² and a wind pressure of 0.80 kN/m² (qp,50).

Section · schematic
Modulemid clampend clampISOTRAP S profile (20–85 mm)2 screws per crest + EPDM
Schematic drawing of the general ISOTRAP S85 build-up. No dimensions from this project are shown.
Technical details
Modules
2,796 × 320 Wp
Module size
1640 × 992 × 35 mm
Roof type
Sandwich · double pitch · 7°
Profile
S85/540 · across ribs
Profile height
85 mm
Fixing
Sealed screw 5.5 × 25
Rib spacing
500 mm
Ground snow load
1.25 kN/m²
Wind pressure
qp,50 = 0.80 kN/m²
FAQ

Which mounting system was used on this roof in Gaziantep?

ISOTEC's short-profile system for sandwich and trapezoidal roofs, ISOTRAP S85. The plant's capacity is 894.72 kWp.

How were the profiles fixed to the roof?

The 540 mm S85 profiles sit across the ribs and are fixed with sealed self-drilling 5.5 × 25 screws, with an EPDM rubber gasket underneath.

Which loads does the structural calculation assume?

The structural report uses snow zone 3 with 1.25 kN/m² ground snow load and 0.80 kN/m² wind pressure; the roof pitch is 7° and the rib spacing 500 mm.

How many modules were installed?

The plant has 2,796 modules of 320 Wp.

From the same country

More ISOTRAP S projects in Türkiye

Planning a project on a sandwich or trapezoidal roof?

Send us the roof covering, the rib spacing and the module size, and we will prepare an ISOTRAP quotation for your project.

Erkan Öztürk

Erkan Öztürk

Founder & CEO @ ISOTEC
Solar Mounting Systems