{"id":49809,"date":"2026-03-15T17:33:41","date_gmt":"2026-03-15T14:33:41","guid":{"rendered":"https:\/\/isotec.com.tr\/?p=49809"},"modified":"2026-03-15T17:43:10","modified_gmt":"2026-03-15T14:43:10","slug":"is-solar-mounting-system-engineering-or-tonnage","status":"publish","type":"post","link":"https:\/\/isotec.com.tr\/eng\/is-solar-mounting-system-engineering-or-tonnage\/","title":{"rendered":"1 MW Solar Power Plant: Engineering or Tonnage?"},"content":{"rendered":"<h2>Same Power Plant, Two Different Quotes<\/h2>\n<p>Imagine you receive two quotes for a 1 MW solar power plant. One proposes a 30-ton steel mounting system, the other a 48-ton system. Both are priced similarly. Which one would you choose?<\/p>\n<p>Most investors think, &quot;48 tons should be stronger.&quot; But in engineering, more material doesn&#039;t always mean better. In fact, sometimes it shows the opposite: <strong>inadequate engineering.<\/strong><\/p>\n<p>This article explains, using technical data, where tonnage discrepancies in solar energy mounting systems come from, the critical errors in calculation methods, and how pricing models mislead investors.<\/p>\n<h2>S450 vs S235: Same Strength, 37% Less Steel<\/h2>\n<p>The quality of steel used in solar energy installation systems directly determines the overall weight of the structure. Here&#039;s a comparison:<\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\">\n<thead>\n<tr style=\"background: #f0f0f0;\">\n<th style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\">Parameter<\/th>\n<th style=\"padding: 12px; border: 1px solid #ddd; text-align: center;\">Design with S235<\/th>\n<th style=\"padding: 12px; border: 1px solid #ddd; text-align: center;\">Design with S450<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Yield Strength<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">235 MPa<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">450 MPa<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Total Steel Per 1 MW<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">~48 tons<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">~30 tons<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Shipping Cost<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">High<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">37% lower<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Foundation Load<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Heavy<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Lightweight \u2014 lowers foundation costs<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Installation Time<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Longer<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Shorter \u2014 lowers labor costs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In the early years of the sector, for 1 MW <strong>60\u201370 tons of steel<\/strong> were used, whereas today, with proper engineering <strong>30 tons\/MW<\/strong> It&#039;s possible. If you&#039;re still receiving offers for 48 tons, the question is: <strong>Is this additional 18 tons a structural requirement, or a product of the calculation methodology?<\/strong><\/p>\n<h2>The Unseen Danger in SAP2000: Lateral Sprains<\/h2>\n<p>One of the most critical control points in steel structure design is <strong>lateral buckling<\/strong>(Lateral Torsional Buckling \u2014 LTB). Especially in solar mounting systems, purlins are subjected to compression at their upper flanges under wind suction loads and are prone to lateral buckling.<\/p>\n<p><strong>Where does the problem begin?<\/strong><\/p>\n<p>In structural analysis programs such as SAP2000, the program <strong>assumes the nodes to be laterally braced by default.<\/strong> When a member is divided at intermediate nodes, each sub-segment is treated as a separate unbraced length. This misleads many engineers, because:<\/p>\n<ul>\n<li>Solar panels do not give the purlins <strong>sufficient lateral support<\/strong>. The panel connection only partially restrains one flange; the opposite flange remains free to buckle.<\/li>\n<li>Under wind uplift, the compression flange is left unrestrained \u2014 compared with the design wind, the structure <strong>at much lower loads<\/strong> can collapse.<\/li>\n<li>Even if the program says &quot;stress is sufficient,&quot; this result is unacceptable if LTB (Low Voltage Testing) is not checked. <strong>is not reliable<\/strong>. The user needs to manually define the unbraced lengths according to the actual situation.<\/li>\n<\/ul>\n<p><strong>So how is it done correctly?<\/strong><\/p>\n<p>To shorten the lateral buckling length, between the profiles <strong>sag rod (cross bracing)<\/strong> is added. The cost of a right rod increases by one cross-sectional size of the profile. <strong>is much more economical<\/strong> \u2014because a 12-16 mm diameter steel bar is many times cheaper than increasing the profile along the entire purlin. Proper engineering doesn&#039;t increase the profile \u2014 it adds lateral support.<\/p>\n<p>Instead of conservatively using a Cb (moment modification) factor of 1.0, calculating it according to the actual moment distribution is also part of section optimization. According to AISC 360, Cb=1.0 is the worst-case assumption (constant moment); in actual load distributions, the Cb value varies between 1.14 and 2.27. With the correct Cb value, the same profile can be achieved at the same safety level. <strong>longer spans<\/strong> can be spanned.<\/p>\n<h2>Wind Load Calculation: TS 498 or Eurocode?<\/h2>\n<p>Wind load is the most crucial parameter in solar energy installation system design. However, the standard used for its calculation fundamentally changes the outcome.<\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\">\n<thead>\n<tr style=\"background: #f0f0f0;\">\n<th style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\">Parameter<\/th>\n<th style=\"padding: 12px; border: 1px solid #ddd; text-align: center;\">TS 498 (Old Turkish Standard)<\/th>\n<th style=\"padding: 12px; border: 1px solid #ddd; text-align: center;\">TS EN 1991-1-4 (Eurocode)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Turbulence Effect<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Not calculated<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Detailed model with turbulence intensity Iv(z).<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Topography Factor<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Limited<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Hills, slopes, and coastlines are modeled separately.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Edge\/Corner Region Separation<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Simplified<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Regional external pressure coefficients (c<sub>pe<\/sub>) \u2014 the edge area is up to twice as high as the center.<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Dynamic Effect<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">It is neglected<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center;\">Structural factor c<sub>s<\/sub>c<sub>d<\/sub> modeled with<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px; border: 1px solid #ddd;\">Conclusion<\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center; color: #c0392b;\"><strong>Significantly lower wind load<\/strong><\/td>\n<td style=\"padding: 10px; border: 1px solid #ddd; text-align: center; color: #27ae60;\"><strong>Realistic and safe.<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Wind load calculated according to TS 498 is based on Eurocode. <strong>between 20% and 40%, depending on the configuration<\/strong> It could be lower. In TS 498, velocity pressure is simply calculated using the formula q = v\u00b2\/1600 \u2014 there is no distinction between turbulence intensity, the first mode frequency of the structure, and the regional pressure coefficient. What does this mean? Choosing a thinner profile means a lighter structure and a &quot;cheaper&quot; offer on paper. But in real wind, this structure will start to stress much earlier than it was designed.<\/p>\n<p><strong>Low wind load = thin profile = cheap quote. But it is also the first plant to fall in a storm.<\/strong><\/p>\n<p>Eurocode is mandatory in Europe. However, in T\u00fcrkiye, projects are still being produced that &quot;pass&quot; using TS 498. Investors only realize the difference when the first serious storm hits.<\/p>\n<h2>Pricing Model: Selling Steel Like a Sack of Flour<\/h2>\n<p>There is a fundamental difference in approach between T\u00fcrkiye and Europe when it comes to pricing solar mounting systems:<\/p>\n<p><strong>European standard: $\/kWp (or cents\/Wp)<\/strong><\/p>\n<ul>\n<li>The price automatically scales up when the panel power increases from 550W to 700W.<\/li>\n<li>The investor directly links the cost of the mounting system to the plant capacity<\/li>\n<li>Quotes for different panel power ratings can be compared<\/li>\n<\/ul>\n<p><strong>T\u00fcrkiye practice: $\/ton<\/strong><\/p>\n<ul>\n<li>The comparison becomes meaningless when the panel power changes.<\/li>\n<li>The tonnage calculated with a 550W panel is not the same as with a 700W panel.<\/li>\n<li>Heavy construction looks less like it&#039;s &quot;expensive&quot; and more like it&#039;s &quot;purchased a larger quantity.&quot;<\/li>\n<\/ul>\n<p>Tonnage-based pricing <strong>rewards heavy construction<\/strong>. More steel = more sales. By reducing weight through clever engineering, the company ends up selling less in the $\/ton model.<\/p>\n<p>kWp-based pricing <strong>rewards engineering quality<\/strong>. A company that can achieve the same capacity with less material offers a more competitive bid to the investor.<\/p>\n<p><strong>The question is simple: Are you buying a mounting system or steel?<\/strong><\/p>\n<h2>Conclusion: Engineering Makes a Difference<\/h2>\n<p>Choosing a solar mounting system is not a steel purchasing decision. It is <strong>an engineering decision.<\/strong>.<\/p>\n<ul>\n<li>The difference between 30 tons and 48 tons stems from the quality of the materials and the calculation method.<\/li>\n<li>A structure that &quot;passes&quot; SAP2000 without lateral buckling control may be unsafe in the field.<\/li>\n<li>Wind loads calculated using TS 498 may not reflect actual conditions.<\/li>\n<li>Pricing based on tonnage rewards heavy construction \u2014 pricing based on kWp rewards smart engineering.<\/li>\n<\/ul>\n<p>Our only question to the investor is: <strong>Are you buying engineering services or tonnage?<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Where does the difference come from between the 30-ton and 48-ton bids for the same 1 MW solar power plant? SAP2000 calculation deficiencies, TS 498 vs Eurocode wind load comparison, and technical analysis of \u20ba\/ton and \u20ba\/kWp pricing models.<\/p>","protected":false},"author":1,"featured_media":49815,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[124,597],"tags":[],"class_list":["post-49809","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-genel","category-teknik"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>1 MW GES: M\u00fchendislik mi, Tonaj m\u0131? - ISOTEC<\/title>\n<meta name=\"description\" content=\"Ayn\u0131 1 MW g\u00fcne\u015f enerjisi santrali i\u00e7in 30 ton ve 48 ton teklif aras\u0131ndaki fark nereden geliyor? SAP2000 hesap eksiklikleri, TS 498 vs Eurocode r\u00fczgar y\u00fck\u00fc kar\u015f\u0131la\u015ft\u0131rmas\u0131 ve \u20ba\/ton ile \u20ba\/kWp fiyatlama modellerinin teknik analizi.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/isotec.com.tr\/eng\/is-solar-mounting-system-engineering-or-tonnage\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131? - ISOTEC\" \/>\n<meta property=\"og:description\" content=\"Ayn\u0131 1 MW g\u00fcne\u015f enerjisi santrali i\u00e7in 30 ton ve 48 ton teklif aras\u0131ndaki fark nereden geliyor? SAP2000 hesap eksiklikleri, TS 498 vs Eurocode r\u00fczgar y\u00fck\u00fc kar\u015f\u0131la\u015ft\u0131rmas\u0131 ve \u20ba\/ton ile \u20ba\/kWp fiyatlama modellerinin teknik analizi.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/isotec.com.tr\/eng\/is-solar-mounting-system-engineering-or-tonnage\/\" \/>\n<meta property=\"og:site_name\" content=\"ISOTEC Solar Montaj Sistemleri\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/isotec.enerji\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-15T14:33:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-15T14:43:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/isotec.com.tr\/wp-content\/uploads\/2026\/03\/20260315-blog-muhendislik-tonaj-172257-scaled.png\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1429\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@isotecsolarTR\" \/>\n<meta name=\"twitter:site\" content=\"@isotecsolarTR\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#\\\/schema\\\/person\\\/954a4990cb5ab80c0493e8434ef05229\"},\"headline\":\"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131?\",\"datePublished\":\"2026-03-15T14:33:41+00:00\",\"dateModified\":\"2026-03-15T14:43:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/\"},\"wordCount\":1158,\"publisher\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/isotec.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/20260315-blog-muhendislik-tonaj-172257-scaled.png\",\"articleSection\":[\"Blog\",\"Teknik\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/\",\"url\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/\",\"name\":\"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131? - ISOTEC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/isotec.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/20260315-blog-muhendislik-tonaj-172257-scaled.png\",\"datePublished\":\"2026-03-15T14:33:41+00:00\",\"dateModified\":\"2026-03-15T14:43:10+00:00\",\"description\":\"Ayn\u0131 1 MW g\u00fcne\u015f enerjisi santrali i\u00e7in 30 ton ve 48 ton teklif aras\u0131ndaki fark nereden geliyor? SAP2000 hesap eksiklikleri, TS 498 vs Eurocode r\u00fczgar y\u00fck\u00fc kar\u015f\u0131la\u015ft\u0131rmas\u0131 ve \u20ba\\\/ton ile \u20ba\\\/kWp fiyatlama modellerinin teknik analizi.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#primaryimage\",\"url\":\"https:\\\/\\\/isotec.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/20260315-blog-muhendislik-tonaj-172257-scaled.png\",\"contentUrl\":\"https:\\\/\\\/isotec.com.tr\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/20260315-blog-muhendislik-tonaj-172257-scaled.png\",\"width\":2560,\"height\":1429,\"caption\":\"Blog muhendislik tonaj\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Teknik\",\"item\":\"https:\\\/\\\/isotec.com.tr\\\/category\\\/teknik\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#website\",\"url\":\"https:\\\/\\\/isotec.com.tr\\\/\",\"name\":\"ISOTEC Solar Montaj Sistemleri\",\"description\":\"Gelecek nesiller i\u00e7in kal\u0131c\u0131 \u00e7\u00f6z\u00fcmler\",\"publisher\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/isotec.com.tr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#organization\",\"name\":\"ISOTEC\",\"url\":\"https:\\\/\\\/isotec.com.tr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/isotec.com.tr\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/isotec_solar_logo__.png\",\"contentUrl\":\"https:\\\/\\\/isotec.com.tr\\\/wp-content\\\/uploads\\\/2022\\\/02\\\/isotec_solar_logo__.png\",\"width\":331,\"height\":152,\"caption\":\"ISOTEC\"},\"image\":{\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/isotec.enerji\\\/\",\"https:\\\/\\\/x.com\\\/isotecsolarTR\",\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q142032843\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/isotec-enerji\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCdj6MJxzrFU8vCcb2LrVdAw\",\"https:\\\/\\\/www.instagram.com\\\/isotecsolar\\\/\",\"https:\\\/\\\/twitter.com\\\/isotecsolarTR\",\"https:\\\/\\\/www.enfsolar.com\\\/isotec-enerji\"],\"legalName\":\"ISOTEC Enerji A.\u015e.\",\"foundingDate\":\"2013\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"\u00c7erke\u015fli Mah. \u0130mes OSB 19. Cad. No:18\",\"postalCode\":\"41455\",\"addressLocality\":\"Dilovas\u0131\",\"addressRegion\":\"Kocaeli\",\"addressCountry\":\"TR\"},\"telephone\":\"+90 262 244 4309\",\"email\":\"info@isotec.com.tr\",\"founder\":[{\"@type\":\"Person\",\"name\":\"Erkan \u00d6zt\u00fcrk\",\"jobTitle\":\"CEO\",\"url\":\"https:\\\/\\\/e-z.team\\\/\",\"image\":\"https:\\\/\\\/commons.wikimedia.org\\\/wiki\\\/Special:FilePath\\\/Erkan_%C3%96zt%C3%BCrk_(ISOTEC),_2026.jpg\",\"sameAs\":[\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q142032832\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/erkanozturk\\\/\"]},{\"@type\":\"Person\",\"name\":\"Zahide \u00d6zt\u00fcrk\",\"jobTitle\":\"CFO\",\"url\":\"https:\\\/\\\/e-z.team\\\/\",\"sameAs\":[\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q142032838\"]}],\"subOrganization\":{\"@type\":\"Organization\",\"name\":\"ISOTEC Solar GmbH\",\"url\":\"https:\\\/\\\/isotecsolar.de\\\/\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Goethestra\u00dfe 4-8\",\"postalCode\":\"60313\",\"addressLocality\":\"Frankfurt am Main\",\"addressCountry\":\"DE\"},\"sameAs\":[\"https:\\\/\\\/www.wikidata.org\\\/wiki\\\/Q142033130\"]}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/isotec.com.tr\\\/#\\\/schema\\\/person\\\/954a4990cb5ab80c0493e8434ef05229\",\"name\":\"admin\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"1 MW Solar Power Plant: Engineering or Tonnage? - ISOTEC","description":"Where does the difference come from between the 30-ton and 48-ton bids for the same 1 MW solar power plant? SAP2000 calculation deficiencies, TS 498 vs Eurocode wind load comparison, and technical analysis of \u20ba\/ton and \u20ba\/kWp pricing models.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/isotec.com.tr\/eng\/is-solar-mounting-system-engineering-or-tonnage\/","og_locale":"en_US","og_type":"article","og_title":"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131? - ISOTEC","og_description":"Ayn\u0131 1 MW g\u00fcne\u015f enerjisi santrali i\u00e7in 30 ton ve 48 ton teklif aras\u0131ndaki fark nereden geliyor? SAP2000 hesap eksiklikleri, TS 498 vs Eurocode r\u00fczgar y\u00fck\u00fc kar\u015f\u0131la\u015ft\u0131rmas\u0131 ve \u20ba\/ton ile \u20ba\/kWp fiyatlama modellerinin teknik analizi.","og_url":"https:\/\/isotec.com.tr\/eng\/is-solar-mounting-system-engineering-or-tonnage\/","og_site_name":"ISOTEC Solar Montaj Sistemleri","article_publisher":"https:\/\/www.facebook.com\/isotec.enerji\/","article_published_time":"2026-03-15T14:33:41+00:00","article_modified_time":"2026-03-15T14:43:10+00:00","og_image":[{"width":2560,"height":1429,"url":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2026\/03\/20260315-blog-muhendislik-tonaj-172257-scaled.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_creator":"@isotecsolarTR","twitter_site":"@isotecsolarTR","twitter_misc":{"Written by":"admin","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#article","isPartOf":{"@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/"},"author":{"name":"admin","@id":"https:\/\/isotec.com.tr\/#\/schema\/person\/954a4990cb5ab80c0493e8434ef05229"},"headline":"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131?","datePublished":"2026-03-15T14:33:41+00:00","dateModified":"2026-03-15T14:43:10+00:00","mainEntityOfPage":{"@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/"},"wordCount":1158,"publisher":{"@id":"https:\/\/isotec.com.tr\/#organization"},"image":{"@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#primaryimage"},"thumbnailUrl":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2026\/03\/20260315-blog-muhendislik-tonaj-172257-scaled.png","articleSection":["Blog","Teknik"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/","url":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/","name":"1 MW Solar Power Plant: Engineering or Tonnage? - ISOTEC","isPartOf":{"@id":"https:\/\/isotec.com.tr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#primaryimage"},"image":{"@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#primaryimage"},"thumbnailUrl":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2026\/03\/20260315-blog-muhendislik-tonaj-172257-scaled.png","datePublished":"2026-03-15T14:33:41+00:00","dateModified":"2026-03-15T14:43:10+00:00","description":"Where does the difference come from between the 30-ton and 48-ton bids for the same 1 MW solar power plant? SAP2000 calculation deficiencies, TS 498 vs Eurocode wind load comparison, and technical analysis of \u20ba\/ton and \u20ba\/kWp pricing models.","breadcrumb":{"@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#primaryimage","url":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2026\/03\/20260315-blog-muhendislik-tonaj-172257-scaled.png","contentUrl":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2026\/03\/20260315-blog-muhendislik-tonaj-172257-scaled.png","width":2560,"height":1429,"caption":"Blog muhendislik tonaj"},{"@type":"BreadcrumbList","@id":"https:\/\/isotec.com.tr\/ges-montaj-sistemi-muhendislik-mi-tonaj-mi\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Teknik","item":"https:\/\/isotec.com.tr\/category\/teknik\/"},{"@type":"ListItem","position":2,"name":"1 MW GES: M\u00fchendislik mi, Tonaj m\u0131?"}]},{"@type":"WebSite","@id":"https:\/\/isotec.com.tr\/#website","url":"https:\/\/isotec.com.tr\/","name":"ISOTEC Solar Mounting Systems","description":"Permanent solutions for future generations","publisher":{"@id":"https:\/\/isotec.com.tr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/isotec.com.tr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/isotec.com.tr\/#organization","name":"ISOTEC","url":"https:\/\/isotec.com.tr\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/isotec.com.tr\/#\/schema\/logo\/image\/","url":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2022\/02\/isotec_solar_logo__.png","contentUrl":"https:\/\/isotec.com.tr\/wp-content\/uploads\/2022\/02\/isotec_solar_logo__.png","width":331,"height":152,"caption":"ISOTEC"},"image":{"@id":"https:\/\/isotec.com.tr\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/isotec.enerji\/","https:\/\/x.com\/isotecsolarTR","https:\/\/www.wikidata.org\/wiki\/Q142032843","https:\/\/www.linkedin.com\/company\/isotec-enerji","https:\/\/www.youtube.com\/channel\/UCdj6MJxzrFU8vCcb2LrVdAw","https:\/\/www.instagram.com\/isotecsolar\/","https:\/\/twitter.com\/isotecsolarTR","https:\/\/www.enfsolar.com\/isotec-enerji"],"legalName":"ISOTEC Enerji A.\u015e.","foundingDate":"2013","address":{"@type":"PostalAddress","streetAddress":"\u00c7erke\u015fli Mah. \u0130mes OSB 19. Cad. No:18","postalCode":"41455","addressLocality":"Dilovas\u0131","addressRegion":"Kocaeli","addressCountry":"TR"},"telephone":"+90 262 244 4309","email":"info@isotec.com.tr","founder":[{"@type":"Person","name":"Erkan \u00d6zt\u00fcrk","jobTitle":"CEO","url":"https:\/\/e-z.team\/","image":"https:\/\/commons.wikimedia.org\/wiki\/Special:FilePath\/Erkan_%C3%96zt%C3%BCrk_(ISOTEC),_2026.jpg","sameAs":["https:\/\/www.wikidata.org\/wiki\/Q142032832","https:\/\/www.linkedin.com\/in\/erkanozturk\/"]},{"@type":"Person","name":"Zahide \u00d6zt\u00fcrk","jobTitle":"CFO","url":"https:\/\/e-z.team\/","sameAs":["https:\/\/www.wikidata.org\/wiki\/Q142032838"]}],"subOrganization":{"@type":"Organization","name":"ISOTEC Solar GmbH","url":"https:\/\/isotecsolar.de\/","address":{"@type":"PostalAddress","streetAddress":"Goethestra\u00dfe 4-8","postalCode":"60313","addressLocality":"Frankfurt am Main","addressCountry":"DE"},"sameAs":["https:\/\/www.wikidata.org\/wiki\/Q142033130"]}},{"@type":"Person","@id":"https:\/\/isotec.com.tr\/#\/schema\/person\/954a4990cb5ab80c0493e8434ef05229","name":"admin"}]}},"_links":{"self":[{"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/posts\/49809","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/comments?post=49809"}],"version-history":[{"count":5,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/posts\/49809\/revisions"}],"predecessor-version":[{"id":49817,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/posts\/49809\/revisions\/49817"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/media\/49815"}],"wp:attachment":[{"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/media?parent=49809"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/categories?post=49809"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/isotec.com.tr\/eng\/wp-json\/wp\/v2\/tags?post=49809"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}